Improving XRD Analysis for Complex Bath Chemistries - Investigations and Challenges Faced
Book chapter

Improving XRD Analysis for Complex Bath Chemistries - Investigations and Challenges Faced

Nursiani Indah Tjahyono, Tania Groutso, David S. Wong, Pascal Lavoie and Mark P. Taylor
Light Metals 2014, pp.571-578
10/03/2014

Abstract

Bath chemistries Bath modifiers Assistant Tennis Coach Excess AlF<inf>3</inf> K Li Mg XRD
An accurate bath composition analysis is essential for regulating an electrolysis cell's mass and thermal balance. XRD is widely utilised in smelters to analyse % excess AlF3 (xsAlF3) and Cryolite Ratio (CR) of bath samples. However, the conventional method of analysis can provide misleading results for the more complex bath chemistries usually found in, but not limited to, Chinese smelters. This complexity is due to the presence of Li, K and Mg constituents coming into the bath from alumina impurities. They react with AlF3 and cryolite, producing additional AlF3-containing phases other than chiolite and Cacryolite, which are not accounted for in the conventional xsAlF3 or CR analysis. Improvement of the xsAlF3 analysis for complex bath chemistries was investigated and presented in this paper. The aim was to provide an XRD methodology to measure the LiF, KF and MgF2 levels in the bath through an intensity calibration method, so that they can be integrated into the xsAlF3 and CR analyses. The challenges faced will also be discussed in this paper.

Metrics

1 Record Views

Details

Logo image