Logo image
Delta-connected cascaded h-bridge converter application in unbalanced load compensation
Conference paper   Peer reviewed

Delta-connected cascaded h-bridge converter application in unbalanced load compensation

Ping-Heng Wu, Hsin-Chih Chen, Yi-Ting Chang and Po-Tai Cheng
IEEE Transactions on Industry Applications, Vol.53(2), pp.1254-1262
03/2017

Abstract

Capacitor voltage-balancing control modular multilevel cascaded converter based on single delta bridge cells (MMCC-SDBC) peak current limit control (PCLC) static compensator (STATCOM) unbalanced load compensation Control and Systems Engineering Industrial and Manufacturing Engineering Electrical and Electronic Engineering
The delta-connected cascaded H-bridge converter has been applied to compensate flicker and unbalance load to meet power quality requirement. Based on the detailed power analysis, this paper presents a dc capacitor voltage-balancing technique for the converter. This paper also proposes a current limit control technique to avoid overstressing the power semiconductor devices of the converter. The control techniques in this paper are verified in a 220-V, 1-kVA laboratory test bench.

Metrics

1 Record Views

Details