Abstract
A specifically designed reference electrode was developed for analyzing the electrochemical behaviors of alloy materials in supercritical water (SCW) environments and identifying the associated electrochemical parameters. In this study, Ag/AgCl reference electrodes and Zr/ZrO2 reference electrodes suitable for high-temperature applications were manufactured and adopted to measure the electrochemical corrosion potentials (ECPs) of 304L stainless steel (SS) and nickel-based alloy 625 in SCW environments with various amounts of dissolved oxygen (DO). The Ag/AgCl reference electrode made in this laboratory was used as a calibration base for the laboratory-made Zr/ZrO2 reference electrode at high temperatures up to 400degC. The two reference electrodes were then used for ECP measurements of 304L SS and alloy 625 specimens in 400degC SCW with various DO levels of 300 ppb, 1 ppm, 8.3 ppm, and 32 ppm and under deaerated conditions. The outcome indicated that concentration increases in DO in the designated SCW environment would yield increases in ECP of the two alloys and they exhibited different ECP responses to DO levels. In addition, the laboratory-made Zr/ZrO2 reference electrode was able to continuously operate for several months and delivered consistent and steady ECP data of the specimens in SCW environments