Micro continuous gas analysis system of ammonia in cleanroom
Conference paper

Micro continuous gas analysis system of ammonia in cleanroom

Aarata Aota, Kazuma Mawatari, Yuko Kihira, Mari Sasaki and Takehiko Kitamori
Proceedings of Conference, MicroTAS 2009 - The 13th International Conference on Miniaturized Systems for Chemistry and Life Sciences, pp.609-611
2009

Abstract

Gas analysis Microfluidics Multiphase flow Phase separation Thermal lens microscopy Chemical Engineering (miscellaneous) Bioengineering
Ammonia in cleanroom air affects reactivity of some photoresist and deteriorates quality of photo-patterning. Therefore, a portable and continuous monitoring system with 1 ppb sensitivity is required. Previously, we have reported ammonia extraction involving 17 times concentration utilizing parallel two-phase microflow and reaction detection in each microchip [1]. Here, we combined the extraction and reaction detection parts in a microchip. We utilized an annular gas-liquid microflow to enhance the extraction. We realized a continuous detection of ammonia with a limit of detection of 2.9 ppb ammonia, namely 29 ppt ammonia gas in a microchip. Further more, we developed an automatic portable prototype system. © 2009 CBMS.