Logo image
Modulate the chamber pressure of the hermetic sealed MEMS device by varying the cavity depth of cap Si
會議論文

Modulate the chamber pressure of the hermetic sealed MEMS device by varying the cavity depth of cap Si

Shyh-Wei Cheng, Jui-Chun Weng, His-Cheng Hsu, Yi-Chiang Sun, Yang-Che Chen 和 Weileun Fang
2015 IEEE SENSORS - Proceedings, 7370692
07/01/2016
Web of Science ID: WOS:000380440800518

摘要

MEMS outgassing WLP Instrumentation Electronic Optical and Magnetic Materials Electrical and Electronic Engineering Spectroscopy
Several kinds of micro-electro-mechanical systems are sensitive to pressure. Some need to interface to ambient condition in order to aim intended function, but others claim hermetic packages to keep the constant internal pressure over MEMS devices operation time [1][2]. This study presents the novel method to control the pressure level of different chambers fabricated using the same wafer-level-packaging (WLP) process. As indicated in Fig. 1, due to the out-gassing of CMOS and MEMS chips both, the chamber pressure of a hermetic sealed MEMS device can be modulated by varying the cavity depth of the cap Si substrate. Thus, pressure of hermetic sealed chambers can be easily specified by the etching depth of capped Si. In applications, the Si-above-CMOS (TSMC 0.18μm 1P5M CMOS process) MEMS process platform has been employed to demonstrate the present approach. The fabrication results demonstrate that the chamber pressure is modulated by the cavity depth of Si cap.