Logo image
Multi-function photovoltaic power supply system with grid-connection and power factor correction features
Conference paper

Multi-function photovoltaic power supply system with grid-connection and power factor correction features

T.-F. Wu, C.-H. Chang and Y.-K. Chen
PESC Record - IEEE Annual Power Electronics Specialists Conference, Vol.3, pp.1185-1190
2000

Abstract

A conventional photovoltaic (PV) inverter system with grid-connection feature is usually composed of a full-bridge inverter and a microprocessor. The PV system is idle when there is no insolation (at nighttime). To optimize the use of the existing components, this paper proposes a multi-function PV power supply system with grid-connection, power factor correction and lamp-driving features. With the synchronous switch technique, pulse-width modulation, additional relays and components, an ordinary, inverter system can function alternately as an electronic ballast with power factor correction at nighttime. Thus. the power switches, driving circuits and the microprocessor in such a multi-function system are optimally used. Computer simulation results and experimental measurements have verified the feasibility of the proposed system.