台北捷運高運量系統軌道對地電位及雜散電流分析
Thesis

台北捷運高運量系統軌道對地電位及雜散電流分析

曾金田
Masters, National Tsing Hua University
2000

Abstract

軌道對地電位一次雜散電流二次雜散電流截流網階梯電路十字路網 rail-to-earth voltageprimary stray currentsecondary stray currentstray current matladder networkcross transportation
For DC traction system, electric current flows from the positive bus of traction substation through the third rail to the vehicle, and returns through the running rails back to the substation. Because the rails are sometimes not well insulated from the earth, part of current then flows into the earth, which is called stray current. The rail-to-earth voltage (touch voltage) is defined as the voltage is between of running rails related to the earth. Stray current may find low resistance way to the earth that is near by pipelines or rebar structures. On the place, where the stray current leaves, the surfaces of metallic pipelines are corroded. Also, when the touch voltage rises, rail maintenance engineers could be hazarded.The stray current and rail-to-earth voltage are influenced by the way of substation grounding. In general, there are three types of grounding that are solidly grounding, high resistance grounding and diode grounding. The diode grounding is presently adopted by the Taipei rapid transit system. Concrete slabs are also used to support the rails and are reinforced with an entity structure that is called stray current mat. Presently, cross transportation is formed with Tamishui - Hsintien line and Pannan line. Their running rails are connected, and their stray current mats under the track of these two lines bed are also connected.The main cause for stray current is the moving vehicles that are accelerating, decelerating and braking. The turned-on and turned-off of drainage diodes between the substation and negative bus (running rails) causes the stray current not flowing in a fixed route. The leakage current of an MRT line could return to the diode-on substation of its neighboring line, which then results in a high rail-to-earth potential. Seeking for better ways to control the stray current and rail-to-earth voltage, including the evaluation of high resistance grounding system, so to replace the existing diode grounding system, TRTC has conducted a series of field tests.The motivation for this thesis study was in view of the past limitations of research on the rail potential and stray current. The past simulation focused on the single vehicle running on only one section, and on the primary leakage current, without considering the secondary leakage current. Further, the aforementioned field tests are lack of the simulation support. As a result, ladder circuit models are proposed in this thesis to simulate the primary and secondary stray current. Also our simulation covers the whole line rather than only one section of the line, and extends into three types of substation grounding. All the field tests conducted by TRTC as mentioned above have been realized by the simulation and compared with the field test results, so to investigate the adaptability of proposed model.

Metrics

1 Record Views

Details

Logo image