Logo image
拋棄式真空模組開發 及其應用於手持式多功能微流體驅動系統
Thesis

拋棄式真空模組開發 及其應用於手持式多功能微流體驅動系統

蔡承翰
Masters, 國立清華大學, 動力機械工程學系
2012

Abstract

形狀記憶高分子 真空模組 微流體 Shape memory polymer vacuum module microfluidic
This thesis developed a novel vacuum module by shape memory polymer. This vacuum module is with the advantages of commercial needs, which are complete structure, easy to casting and massive production low price, and reusable. This vacuum module is easy to attach and integrated into microsystem chips, further to achieve multi-step microfluidic driving. This thesis also develop a handheld multifunctional microfluidic driving device, and microfluidic can be multi-controlled its flow rate and flow amount by this portable device. In the past, there are many microfluidic elements and systems have been developed. Yet due to the main goal of the research are expected to achieve the point-of-care system, there are many issues need to be concerned, such as enormous size, high prize, loss of sample, complicated fabrication, and cannot be multi-controlled, most of researches are not suitable enough. However, the vacuum module developed in this thesis has improved the disadvantages we have mentioned. Our developed vacuum module without any tubing connection has achieved the requirement of point-of-care handheld system. This research can be separated to three parts, the first part is improve the mechanical properties and stability of vacuum modules and measure the recovery distance and vacuum pressure of vacuum module. In order to improve then mechanical properties and stability, we use PTFE (Polytetrafluoroethene) as the material of mold. It makes vacuum module can be produced massively. In the same time, we also reduced the size of vacuum module to 2 cm x 2 cm cube, and the height is adjustable between 0.5 mm ~ 1.5 mm for different vacuum pressure requirement. In the other hand, the flatten rate of temporary shape is up to 99.28%, and the recovery rate of shape memory effect maintain 98%. We also investigate reusability, temperature of hot embossing and the depth of cavity. The second part, we have designed the PID (Proportion Integration Differentiation) controller to control the heating source of vacuum module. In the same time, we use PID controller to adjust driving time of microfluidic and flow rate. In the condition of constant currant 150 mA to micro heating pad as the heating resource of vacuum module, the shape memory effect finish after 300 second, and after PID controller control the heating source, the reaction time can be reduced to 150 second. For the dynamic pressure measurement, the relation between volume and maximum pressure is linear, and the maximum differential pressure is -7.2 psi. For the microfluidic driving, with PID controller, the average flow rate is 26.028 µl / min. The maximum flow rate can be up to 90.9375 µl / min. The flow rate is adjustable. The third part is combine vacuum module with handheld C-reactive protein sensing chip to develop a point-of-care biomedical system. This thesis has developed a handheld multifunctional microfluidic driving system using a 9 V battery as power supply to the micro heating pad. Using the developed system can successfully achieve single microfluidic driving, two-stage microfluidic driving, and four-stage microfluidic driving.

Metrics

1 Record Views

Details

Logo image