Logo image
相變型散熱元件之性能量測系統之研發
Thesis

相變型散熱元件之性能量測系統之研發

張國瀚
Masters, 國立清華大學, 工程與系統科學系
2010

Abstract

均溫板 熱管 熱阻 擴散熱阻 vapor chambers heat pipe thermal resistance spread thermal resistance
A multipurpose of the performance measuring system for the phase change heat transport device such as heat pipe, vapor chamber and defrost plate was designed in this study. The characteristic of this measuring system was using thermal electrical chip (T.E.C.) as the condenser,which can exactly control the temperature in adiabatic section and condenser section. Therefore, it is effective to reduce the experimenting time and increase the accuracy of performance Test. This paper also present experimental measurement of performance of a vapor chamber (VC), heat pipe and defrost plate. The vapor chamber, with square sides of 50 x 50mm and thickness of 3.5mm and 6mm, was sandwiched between a heater block and a cooling plate located on the evaporator and the condenser surface respectively. The performance of the vapor chamber was investigated by determining the thermal resistance over a heat input range of 1 to 5W in natural convection test with the condenser opens at ambient environment and up to 40W in force convection with the condenser held at constant temperature. The experimental results show that the Maximum heat dissipated ability was the same compare with the new design measuring system and the traditional heat pipe performance measuring system with a water jacket as the cooling condenser. The thermal resistance in natural convection condition for the axial direction was around 0.1℃/W, while the spray thermal resistance was 0.12℃/W. For the defrost plate, the axial thermal resistance was 0.17℃/W and 0.18℃/W for the spray thermal resistance. Keywords: vapor chambers, heat pipe, thermal resistance, spread thermal resistance

Metrics

1 Record Views

Details

Logo image