Capacitors;Charge pumps;Neurons;Computer architecture;Voltage control;Satellite broadcasting;Wireless communication
Although deep brain stimulation (DBS) has been a promising alternative for treating several neural disorders, the mechanisms underlying the DBS remain not fully understood. As rat models provide the advantage of recording and stimulating different disease-related regions simultaneously, this paper proposes a battery-less, implantable neuro-electronic interface suitable for studying DBS mechanisms with a freely-moving rat. The neuro-electronic interface mainly consists of a microsystem able to interact with eight different brain regions bi-directionally and simultaneously. To minimize the size of the implant, the microsystem receives power and transmits data through a single coil. In addition, particular attention is paid to the capability of recording neural activities right after each stimulation, so as to acquire information on how stimulations modulate neural activities. The microsystem has been fabricated with the standard 0.18 μm CMOS technology. The chip area is 7.74 mm 2, and the microsystem is able to operate with a single supply voltage of 1 V. The wireless interface allows a maximum power of 10 mW to be transmitted together with either uplink or downlink data at a rate of 2 Mbps or 100 kbps, respectively. The input referred noise of recording amplifiers is 1.16 μVrms, and the stimulation voltage is tunable from 1.5 V to 4.5 V with 5-bit resolution. After the electrical functionality of the microsystem is tested, the capability of the microsystem to interface with rat brain is further examined and compared with conventional instruments. All experimental results are presented and discussed in this paper.

相關連結

指標

100 readers on Mendeley
1 readers on CiteULike

InCites亮點

本研究成果之相關指標(擷取自 InCites Benchmarking & Analytics)

引用書目主題
1 Clinical & Life Sciences
1.82 Gait & Posture
1.82.1144 Neural Interfaces
Web Of Science研究領域
Engineering, Biomedical
Engineering, Electrical & Electronic
ESI研究領域
Engineering

詳細資料

Logo image