A Monte Carlo study of bone-tissue interface microdosimeters
期刊文章   同儕審查

A Monte Carlo study of bone-tissue interface microdosimeters

I-Chun Cho, Fang-Hsin Chen, Tsi-Chian ChaoChuan-Jong Tung
Applied Radiation and Isotopes, 卷.140, 頁碼.193-200
10/2018
PMID: 30048920

摘要

B100 Bone Lineal energy Microdosimetry TEPC Radiation
Radiation-induced bone diseases were frequently reported in radiotherapy patients. To study the diseases, microdosimeters were constructed with walls of A150-A150, A150-B100, B100-A150 and B100-B100 interfaces. Monte Carlo simulations of these microdosimeters were performed to determine the lineal energy spectra of an interface site at different depths in water for 230 MeV protons. Comparing these spectra with data of ICRU tissue and bone walls, better agreements were found at shallow depths for protons and delta-rays than deep depths for nuclear interactions.