Logo image
A Portable Neck-Surface Piezoelectric Sensor for Evaluating Subclinical Carotid Atherosclerosis via Snoring Vibratory Analysis: An Exploratory Dual-Modality Study
期刊文章   開放取用(OA)   同儕審查

A Portable Neck-Surface Piezoelectric Sensor for Evaluating Subclinical Carotid Atherosclerosis via Snoring Vibratory Analysis: An Exploratory Dual-Modality Study

Li-Ang Lee, Li-Pang Chuang, Guo-She Lee, Cheng-Kuo Lai, Huei-Dan Cheng, Zi-Xuan Huang, Zong-Han Lee, Liang-Yu Shyu, Hsueh-Yu Li, Chi-Hung Liu, …
Biosensors (Basel), 卷.16(8), 頁.428
06/08/2026
PMID: 42645046
Web of Science ID: WOS:001859846800001

摘要

Chemistry Chemistry, Analytical Instruments & Instrumentation Nanoscience & Nanotechnology Science & Technology Science & Technology - Other Topics Physical Sciences Technology
Obstructive sleep apnea syndrome (OSAS) is heavily implicated in subclinical cardiovascular disease; however, traditional polysomnographic metrics fail to capture the localized mechanical trauma exerted on the carotid artery. To address this methodological gap, this study evaluated exploratory associations between frequency-domain snoring characteristics and right carotid artery alterations in 50 patients with OSAS. Snoring was quantified using a dual-modality bioelectronic approach: an ambient microphone captured airborne snoring sound energy (SSE), while a portable neck-surface piezoelectric sensor recorded tissue-conducted snoring vibratory energy (SVE). Subclinical vascular changes, including carotid intima-media thickness (CIMT) and atherosclerosis, were assessed via ultrasonography. Hierarchical multivariable regression demonstrated that acoustic SSE%-404-500 Hz and mechanical SVE%-112-144 Hz independently correlated with preliminary CIMT increases (adjusted beta = 0.033 and 0.021, respectively; both p < 0.05), alongside neck circumference. Conversely, SSE%-404-500 Hz emerged as an exploratory marker for focal carotid atherosclerosis (adjusted odds ratio = 1.828; p = 0.009). Integrating this metric with baseline parameters yielded exploratory diagnostic capacity (area under the curve = 0.833; p < 0.001), achieving 89% sensitivity and 69% specificity. These findings suggest that dual-modality spectral analysis provides a non-invasive exploratory framework for cardiovascular risk stratification, isolating localized mechanotransduction phenotypes independently of systemic hypoxia.

檔案與連結 (2)

pdf
2026-A Portable Neck-Surface Piezoelectric Sensor for Evaluating Subclinical Carotid Atherosclerosis via Snoring Vibratory Analysis_An Exploratory Dual-Modality Study7.85 MB下載檢視
開放存取(OA)
url
https://doi.org/10.3390/bios16080428檢視
已出版(紀錄版本)

相關連結

指標

1 檢視次數

詳細資料

Logo image