Logo image
A novel impedimetric biosensor based on titanium nitride nano-electrode arrays for influenza A H1N1 testing
期刊文章

A novel impedimetric biosensor based on titanium nitride nano-electrode arrays for influenza A H1N1 testing

Y.-C. Li, S.-T. Cheng, C.-L. Lien, J.-H. Shiau, C.-F. Shen 和 C.-M. Cheng
Sensors and Actuators Reports, 卷.10
2025
Web of Science ID: WOS:001583258500001

摘要

Biosensor Complementary metal-oxide-semiconductor Electrochemical impedance spectroscopy Impedimetric sensor Influenza A H1N1 Nano-electrode arrays Titanium nitride Antigens Biocompatibility Charge transfer Diagnosis Diseases Electrochemical electrodes MOS devices Oxide semiconductors Semiconductor device manufacture Semiconductor device structures Titanium oxides Viruses Complementary metal oxide semiconductors Electrochemical-impedance spectroscopies Electrode arrays Impedimetric biosensors Impedimetric sensor Influenza A Influenza A h1n1 Nano-electrode array Nanoelectrode Titania Biosensors Electrochemical impedance spectroscopy Titanium nitride
The development of point-of-care testing devices for real-time detection of influenza A H1N1 virus is critical for early diagnosis, and for continuous disease monitoring. In this study, we developed a novel impedimetric biosensor for detecting influenza A H1N1 virus, using a nano-electrode array fabricated through standard complementary metal-oxide-semiconductor technology. Each nano-electrode is a raised structure with a radius of 100 nanometers and a height of 200 nanometers. Titanium nitride was chosen as the electrode material for its biocompatibility and compatibility with semiconductor processes. The electrode surfaces were modified by diazonium electrografting to introduce carboxyl groups, which enabled antibody immobilization via carbodiimide coupling chemistry. We analyzed the relationship between the reduction peak current and the percentage change in charge transfer resistance before and after each modification step, and further examined the correlation between changes during modification and antibody binding. The completed biosensor successfully detected influenza A H1N1 antigens in phosphate-buffered saline, achieving a detection limit of 0.00025 EU/mL. The sensor's response also showed a strong positive correlation with viral RNA content (Pearson r = 0.9702), indicating its potential for quantitative virus detection. These results demonstrate the feasibility of using semiconductor-based nano-electrode array biosensors for point-of-care infectious disease diagnostics. © 2025 The Author(s)

檔案與連結 (2)

url
https://www.scopus.com/inward/record.uri?eid=2-s2.0-105016257127&doi=10.1016%2fj.snr.2025.100384&partnerID=40&md5=79b294c80314de6265c07dbbe35ccfcf檢視
url
https://doi.org/10.1016/j.snr.2025.100384檢視
已出版(紀錄版本) 開放

相關連結

指標

1 檢視次數

詳細資料

Logo image