A proton beam therapy system dedicated to spot-scanning increases accuracy with moving tumors by real-time imaging and gating and reduces equipment size

Shinichi Shimizu, Naoki Miyamoto, Taeko Matsuura, Yusuke Fujii, Masumi Umezawa, Kikuo Umegaki, Kazuo Hiramoto, Hiroki Shirato 和 Fang-Hsin Chen
PloS one, 卷.9(4), 頁.e94971
01/04/2014
PMID: 24747601
Web of Science ID: WOS:000335226500048

摘要

Carcinoma, Hepatocellular - diagnostic imaging Carcinoma, Hepatocellular - physiopathology Carcinoma, Hepatocellular - radiotherapy Fiducial Markers Fluoroscopy Humans Liver Neoplasms - diagnostic imaging Liver Neoplasms - physiopathology Liver Neoplasms - radiotherapy Movement Proton Therapy - instrumentation Proton Therapy - standards Radiotherapy Dosage Respiration Respiratory-Gated Imaging Techniques Synchrotrons Tomography, X-Ray Computed
A proton beam therapy (PBT) system has been designed which dedicates to spot-scanning and has a gating function employing the fluoroscopy-based real-time-imaging of internal fiducial markers near tumors. The dose distribution and treatment time of the newly designed real-time-image gated, spot-scanning proton beam therapy (RGPT) were compared with free-breathing spot-scanning proton beam therapy (FBPT) in a simulation. In-house simulation tools and treatment planning system VQA (Hitachi, Ltd., Japan) were used for estimating the dose distribution and treatment time. Simulations were performed for 48 motion parameters (including 8 respiratory patterns and 6 initial breathing timings) on CT data from two patients, A and B, with hepatocellular carcinoma and with clinical target volumes 14.6 cc and 63.1 cc. The respiratory patterns were derived from the actual trajectory of internal fiducial markers taken in X-ray real-time tumor-tracking radiotherapy (RTRT). With FBPT, 9/48 motion parameters achieved the criteria of successful delivery for patient A and 0/48 for B. With RGPT 48/48 and 42/48 achieved the criteria. Compared with FBPT, the mean liver dose was smaller with RGPT with statistical significance (p<0.001); it decreased from 27% to 13% and 28% to 23% of the prescribed doses for patients A and B, respectively. The relative lengthening of treatment time to administer 3 Gy (RBE) was estimated to be 1.22 (RGPT/FBPT: 138 s/113 s) and 1.72 (207 s/120 s) for patients A and B, respectively. This simulation study demonstrated that the RGPT was able to improve the dose distribution markedly for moving tumors without very large treatment time extension. The proton beam therapy system dedicated to spot-scanning with a gating function for real-time imaging increases accuracy with moving tumors and reduces the physical size, and subsequently the cost of the equipment as well as of the building housing the equipment.

檔案與連結 (1)

url
https://doi.org/10.1371/journal.pone.0094971檢視
已出版(紀錄版本) 開放

相關連結

詳細資料

Logo image