Logo image
A vision transformer-convolutional neural network framework for decision-transparent dual-energy X-ray absorptiometry recommendations using chest low-dose CT
期刊文章   同儕審查

A vision transformer-convolutional neural network framework for decision-transparent dual-energy X-ray absorptiometry recommendations using chest low-dose CT

Duen-Pang Kuo, Yung-Chieh Chen, Sho-Jen Cheng, Kevin Li-Chun Hsieh, Yi-Tien Li, Po-Chih Kuo, Yung-Chun Chang 和 Cheng-Yu Chen
International journal of medical informatics (Shannon, Ireland), 卷.199, 頁.105901
01/07/2025
PMID: 40187299
Web of Science ID: WOS:001465497000001

摘要

Bone mineral density Convolutional Neural Network dual-energy X-ray absorptiometry Low-dose computed tomography Vision Transformer
•A ViT–CNN model outperforms individual models in bone classification using chest LDCT.•Thoracic FOV size affects model performance in bone classification.•A visualized DXA recommendation supports decision-making in clinical practice.•The framework improves accuracy and applicability in osteoporosis screening. This study introduces an ensemble framework that integrates Vision Transformer (ViT) and Convolutional Neural Networks (CNN) models to leverage their complementary strengths, generating visualized and decision-transparent recommendations for dual-energy X-ray absorptiometry (DXA) scans from chest low-dose computed tomography (LDCT). The framework was developed using data from 321 individuals and validated with an independent test cohort of 186 individuals. It addresses two classification tasks: (1) distinguishing normal from abnormal bone mineral density (BMD) and (2) differentiating osteoporosis from non-osteoporosis. Three field-of-view (FOV) settings—fitFOV (entire vertebra), halfFOV (vertebral body only), and largeFOV (fitFOV + 20 %)—were analyzed to assess their impact on model performance. Model predictions were weighted and combined to enhance classification accuracy, and visualizations were generated to improve decision transparency. DXA scans were recommended for individuals classified as having abnormal BMD or osteoporosis. The ensemble framework significantly outperformed individual models in both classification tasks (McNemar test, p < 0.001). In the development cohort, it achieved 91.6 % accuracy for task 1 with largeFOV (area under the receiver operating characteristic curve [AUROC]: 0.97) and 86.0 % accuracy for task 2 with fitFOV (AUROC: 0.94). In the test cohort, it demonstrated 86.6 % accuracy for task 1 (AUROC: 0.93) and 76.9 % accuracy for task 2 (AUROC: 0.99). DXA recommendation accuracy was 91.6 % and 87.1 % in the development and test cohorts, respectively, with notably high accuracy for osteoporosis detection (98.7 % and 100 %). This combined ViT–CNN framework effectively assesses bone status from LDCT images, particularly when utilizing fitFOV and largeFOV settings. By visualizing classification confidence and vertebral abnormalities, the proposed framework enhances decision transparency and supports clinicians in making informed DXA recommendations following opportunistic osteoporosis screening.

相關連結

指標

1 檢視次數

詳細資料

Logo image