Logo image
Advanced diffusion models in head and neck squamous cell carcinoma patients: Goodness of fit, relationships among diffusion parameters and comparison with dynamic contrast-enhanced perfusion
期刊文章   同儕審查

Advanced diffusion models in head and neck squamous cell carcinoma patients: Goodness of fit, relationships among diffusion parameters and comparison with dynamic contrast-enhanced perfusion

Noriyuki Fujima, Tomohiro Sakashita, Akihiro Homma, Yukie Shimizu, Atsushi Yoshida, Taisuke Harada, Khin Khin Tha, Kohsuke Kudo, Hiroki Shirato 和 Fang-Hsin Chen
Magnetic resonance imaging, 卷.36, 頁碼.16-23
01/02/2017
PMID: 27989906
Web of Science ID: WOS:000393536100004

摘要

Advanced fitting models Diffusion weighted imaging Dynamic contrast-enhanced perfusion Head and neck squamous cell carcinoma
We assessed advanced fitting models of diffusion weighted imaging (DWI) in head/neck squamous cell carcinoma (HNSCC) patients to determine the best goodness of fit and correlations among diffusion parameters. We compared these results with those of dynamic contrast-enhanced (DCE) perfusion parameters. We retrospectively evaluated 32 HNSCC patients (12 sinonasal, 20 pharynx/oral cavity). The DWI acquisition used single-shot spin-echo echo-planar imaging (EPI) with 12 b-values (0−2000). We calculated 14 DWI parameters using mono-exponential, bi-exponential, and tri-exponential models, stretched exponential model (SEM) and diffusion kurtosis imaging (DKI) models. We compared each model's goodness of fit using the residual sum of squares (RSS), Akaike Information Criterion (AIC) and Bayesian information criterion (BIC) value. We determined the correlation between each pair of DWI parameters and between each DWI parameter and DCE perfusion parameter. The tri-exponential fit's RSS, AIC and BIC values were significantly smaller than those for bi-exponential fit. The RSS, AIC and BIC values of the SEM fit and DKI fit were significantly smaller than mono-exponential model. Significant correlations were observed in 30 pairs (sinonasal cavity) and 31 (sinonasal cavity group) among 91 DWI parameter combinations. Significant correlations were also observed in nine pairs (both sinonasal cavity and pharynx/oral cavity group) among 64 DWI/DCE perfusion parameter pairs, in particular, high positive correlations between the tri-exponential model's intermediate diffusion fraction (f2) and the volume of the extracellular extravascular space per unit volume of tissue (ve) were observed in both patient groups. We identified several correlations between DWI parameters by advanced fitting models and correlations between DWI and DCE parameters. These will help determine HNSCC patients' detailed tissue structures.

檔案與連結 (1)

url
https://doi.org/10.1016/j.mri.2016.10.024檢視
已出版(紀錄版本) 開放

相關連結

詳細資料

Logo image