Logo image
Artificial intelligence-enabled electrocardiographic screening for left ventricular systolic dysfunction and mortality risk prediction
期刊文章   同儕審查

Artificial intelligence-enabled electrocardiographic screening for left ventricular systolic dysfunction and mortality risk prediction

Yu-Chang Huang, Yu-Chun Hsu, Zhi-Yong Liu, Ching-Heng Lin, Richard Tsai, Jung-Sheng Chen, Po-Cheng Chang, Hao-Tien Liu, Wen-Chen Lee, Hung-Ta Wo, …
Frontiers in cardiovascular medicine, 卷.10, 頁.1070641
03/03/2023
PMID: 36960474
Web of Science ID: WOS:000950908300001

摘要

Cardiac & Cardiovascular Systems Cardiovascular System & Cardiology Life Sciences & Biomedicine Science & Technology
BackgroundLeft ventricular systolic dysfunction (LVSD) characterized by a reduced left ventricular ejection fraction (LVEF) is associated with adverse patient outcomes. We aimed to build a deep neural network (DNN)-based model using standard 12-lead electrocardiogram (ECG) to screen for LVSD and stratify patient prognosis. MethodsThis retrospective chart review study was conducted using data from consecutive adults who underwent ECG examinations at Chang Gung Memorial Hospital in Taiwan between October 2007 and December 2019. DNN models were developed to recognize LVSD, defined as LVEF <40%, using original ECG signals or transformed images from 190,359 patients with paired ECG and echocardiogram within 14 days. The 190,359 patients were divided into a training set of 133,225 and a validation set of 57,134. The accuracy of recognizing LVSD and subsequent mortality predictions were tested using ECGs from 190,316 patients with paired data. Of these 190,316 patients, we further selected 49,564 patients with multiple echocardiographic data to predict LVSD incidence. We additionally used data from 1,194,982 patients who underwent ECG only to assess mortality prognostication. External validation was performed using data of 91,425 patients from Tri-Service General Hospital, Taiwan. ResultsThe mean age of patients in the testing dataset was 63.7 +/- 16.3 years (46.3% women), and 8,216 patients (4.3%) had LVSD. The median follow-up period was 3.9 years (interquartile range 1.5-7.9 years). The area under the receiver-operating characteristic curve (AUROC), sensitivity, and specificity of the signal-based DNN (DNN-signal) to identify LVSD were 0.95, 0.91, and 0.86, respectively. DNN signal-predicted LVSD was associated with age- and sex-adjusted hazard ratios (HRs) of 2.57 (95% confidence interval [CI], 2.53-2.62) for all-cause mortality and 6.09 (5.83-6.37) for cardiovascular mortality. In patients with multiple echocardiograms, a positive DNN prediction in patients with preserved LVEF was associated with an adjusted HR (95% CI) of 8.33 (7.71 to 9.00) for incident LVSD. Signal- and image-based DNNs performed equally well in the primary and additional datasets. ConclusionUsing DNNs, ECG becomes a low-cost, clinically feasible tool to screen LVSD and facilitate accurate prognostication.

檔案與連結 (1)

url
https://doi.org/10.3389/fcvm.2023.1070641檢視
已出版(紀錄版本) 開放

相關連結

詳細資料

Logo image