Bacteria detection utilizing electrical conductivity
Journal article   Peer reviewed

Bacteria detection utilizing electrical conductivity

Yi-Chun Lu, Ya-Shuan Chuang, Yi-Yang Chen, An-Chi Shu, Hsing-Yu Hsu, Hwan-You Chang and Tri-Rung Yew
Biosensors and Bioelectronics, Vol.23(12), pp.1856-1861
15/07/2008

Abstract

Antibody immobilization Bacteria detection Bacteria immobilization Biosensor Escherichia coli (E. coli Interdigitated electrode array JM109)
Real-time and specific detection of single bacterium remains a fundamental challenge and draws very much attention. Using test patterns composed of interdigitated Au-electrode arrays modified with antibody, the specific and quantitative detection of the electrical conductivity of a single Escherichia coli (E. coli, JM109) has been carried out in this work. The key is to ensure low background current of the antibody-modified test patterns before bacteria detection (<0.7 pA in this case) and minimize the residual moisture or hydration after E. coli immobilization, such as via the use of 1-min bake at 50 °C prior to electrical measurement. This method holds great potential for future application in the real-time, specific, and quantitative bacterium detection down to a single bacterium cell. © 2008 Elsevier B.V. All rights reserved.