Bio-impedance measurement optimization for high-resolution carotid pulse sensing
期刊文章   開放取用(OA)   同儕審查

Bio-impedance measurement optimization for high-resolution carotid pulse sensing

Ting-Wei Wang, Hsiao-Wei Chu, Lin Chou, Yen-Ling Sung, Yuan-Ta Shih, Po-Chun Hsu, Hao-Min ChengShien-Fong Lin
Sensors, 卷.21(5), 頁碼.1-13
03/2021
PMID: 33668822
Web of Science ID: WOS:000628536100001

摘要

Bio-impedance measurement Cardiovascular monitoring Carotid pulse sensing Continuous blood pressure Hemodynamics Impedance plethysmography (IPG) Analytical Chemistry Information Systems Atomic and Molecular Physics and Optics Biochemistry Instrumentation Electrical and Electronic Engineering
Continuous hemodynamic monitoring is important for long-term cardiovascular healthcare, especially in hypertension. The impedance plethysmography (IPG) based carotid pulse sensing is a non-invasive diagnosis technique for measuring pulse signals and further evaluating the arterial conditions of the patient such as continuous blood pressure (BP) monitoring. To reach the high-resolution IPG-based carotid pulse detection for cardiovascular applications, this study provides an optimized measurement parameter in response to obvious pulsation from the carotid artery. The influence of the frequency of excitation current, electrode cross-sectional area, electrode arrangements, and physiological site of carotid arteries on IPG measurement resolution was thoroughly investigated for optimized parameters. In this study, the IPG system was implemented and installed on the subject’s neck above the carotid artery to evaluate the measurement parameters. The measurement results within 6 subjects obtained the arterial impedance variation of 2137 mΩ using the optimized measurement conditions, including excitation frequency of 50 kHz, a smaller area of 2 cm 2 , electrode spacing of 4 cm and 1.7 cm for excitation and sensing functions, and location on the left side of the neck. The significance of this study demonstrates an optimized measurement methodology of IPG-based carotid pulse sensing that greatly improves the measurement quality in cardiovascular monitoring.

檔案與連結 (2)

url
https://doi.org/10.3390/s21051600檢視
已出版(紀錄版本) 開放
url
https://www.mdpi.com/1424-8220/21/5/1600檢視

相關連結

InCites亮點

本研究成果之相關指標(擷取自 InCites Benchmarking & Analytics)

合作類型
機構合作
引用書目主題
1 Clinical & Life Sciences
1.55 Cardiorenal Medicine
1.55.860 Arterial Stiffness
Web Of Science研究領域
Chemistry, Analytical
Engineering, Electrical & Electronic
Instruments & Instrumentation
ESI研究領域
Chemistry

聯合國永續發展目標(SDGs)

此研究成果有助於達成以下目標:

#3 Good Health and Well-Being

來源:來自InCites的SDGs

詳細資料

Logo image