Breath-holding during the Calibration Scan Improves the Reproducibility of Parallel Transmission at 7T for Human Brain
期刊文章

Breath-holding during the Calibration Scan Improves the Reproducibility of Parallel Transmission at 7T for Human Brain

Taisuke Harada, Kohsuke Kudo, Ikuko Uwano, Fumio Yamashita, Hiroyuki Kameda, Tsuyoshi Matsuda, Makoto Sasaki, Hiroki Shirato 和 Fang-Hsin Chen
Magnetic resonance in medical sciences, 卷.16(1), 頁碼.23-31
01/01/2017
PMID: 27001392
Web of Science ID: WOS:000392690700004

摘要

Life Sciences & Biomedicine Radiology, Nuclear Medicine & Medical Imaging Science & Technology
Purpose: The B0 and B1+ maps required for calculation of the radiofrequency (RF) pulse of parallel transmission (pTx) are obtained in calibration scans; however, they may be affected by respiratory motion. We aimed to compare the reproducibility of B0 and B1+ maps and gradient echo (GRE) images of the brain scanned with pTx at 7T between free-breathing (FB) and breath-holding (BH) conditions during the calibration scan. Methods: Nine healthy volunteers were scanned by 7T MRI using a two-channel quadrature head coil. In the pTx calibration scans performed with FB and BH, the B0 map was obtained from two different TE images and the B1+ map was calculated by the Bloch-Siegert method. A GRE image (gradient-recalled acquisition in steady state) was also obtained with RF shimming and RF design of pTx with spoke method, as well as quadrature transmission (qTx). All the scans were repeated over five sessions. The reproducibility of the B0 and B1+ maps and GRE image was evaluated with region-of-interest measurements using inter-session standard deviation (SD) and coefficient of variation (CV) values. Intensity homogeneity of GRE images was also assessed with in-plane CV. Results: Inter-session SDs of B0 and B1+ maps were significantly smaller in BH (P < 0.01). Inter-session CVs of GRE images were significantly smaller in qTx than BH and FB (P < 0.01, both); however, the CVs of BH were significantly smaller (P < 0.01). In-plane CVs of FB and BH with RF shimming were not significantly different with qTx; however, CVs of FB and BH with RF design were significantly smaller than those of qTx (P < 0.05 and P < 0.01, respectively). Conclusion: BH could improve the reproducibility of B0 and B1+ maps in pTx calibration scans and GRE images. These results might facilitate the development of pTx in human brain at 7T.

檔案與連結 (1)

url
https://doi.org/10.2463/mrms.mp.2015-0137檢視
已出版(紀錄版本) 開放

相關連結

詳細資料

Logo image