Logo image
Characterization of Acoustic Droplet Vaporization for Control of Bubble Generation Under Flow Conditions
Journal article   Peer reviewed

Characterization of Acoustic Droplet Vaporization for Control of Bubble Generation Under Flow Conditions

Shih-Tsung Kang, Yi-Luan Huang and Chih-Kuang Yeh
Ultrasound in Medicine and Biology, Vol.40(3), pp.551-561
03/2014

Abstract

Acoustic droplet vaporization Diffusion-assisted bubble growth Flow condition Perfluorocarbon droplet Size control and manipulation
This study investigated the manipulation of bubbles generated by acoustic droplet vaporization (ADV) under clinically relevant flow conditions. Optical microscopy and high-frequency ultrasound imaging were used to observe bubbles generated by 2-MHz ultrasound pulses at different time points after the onset of ADV. The dependence of the bubble population on droplet concentration, flow velocity, fluid viscosity and acoustic parameters, including acoustic pressure, pulse duration and pulse repetition frequency, was investigated. The results indicated that post-ADV bubble growth spontaneously driven by air permeation markedly affected the bubble population after insonation. The bubbles can grow to a stable equilibrium diameter as great as twice the original diameter in 0.5-1s, as predicted by the theoretical calculation. The growth trend is independent of flow velocity, but dependent on fluid viscosity and droplet concentration, which directly influence the rate of gas uptake by bubbles and the rate of gas exchange across the wall of the semipermeable tube containing the bubbles and, hence, the gas content of the host medium. Varying the acoustic pressure does not markedly change the formation of bubbles as long as the ADV thresholds of most droplets are reached. Varying pulse duration and pulse repetition frequency markedly reduces the number of bubbles. Lengthening pulse duration favors the production of large bubbles, but reduces the total number of bubbles. Increasing the PRF interestingly provides superior performance in bubble disruption. These results also suggest that an ADV bubble population cannot be assessed simply on the basis of initial droplet size or enhancement of imaging contrast by the bubbles. Determining the optimal acoustic parameters requires careful consideration of their impact on the bubble population produced for different application scenarios. © 2014 World Federation for Ultrasound in Medicine & Biology.

Metrics

1 Record Views

Details

Logo image