Logo image
Comparison of different methods for the shielding analysis of an AB-BNCT facility based on the Be(p,xn) reaction with 30-MeV protons
期刊文章   同儕審查

Comparison of different methods for the shielding analysis of an AB-BNCT facility based on the Be(p,xn) reaction with 30-MeV protons

Bo-Lun Lai, Yu-Shiang Huang, Po-Chen Lai, Wei-Han ChuRong-Jiun Sheu
Applied Radiation and Isotopes, 卷.166, 109351
12/2020

摘要

Accelerator-based neutron source Boron neutron capture therapy Hybrid method Monte Carlo Point-source line-of-sight approximation Variance reduction Radiation
Five shielding calculation methods were employed to estimate the dose rate distribution around an accelerator-based boron neutron capture therapy facility. Their performances were compared in terms of accuracy and efficiency. The results indicate that the hybrid deterministic/Monte Carlo method is the most efficient in the context of accurate modeling and simulation, whereas the analytical approximation with pre-generated source terms and attenuation lengths is preferable in the design phase because of its simplicity and ease of verification while retaining a reasonable accuracy.