Deep learning with test-time augmentation for radial endobronchial ultrasound image differentiation: a multicentre verification study
期刊文章   開放取用(OA)

Deep learning with test-time augmentation for radial endobronchial ultrasound image differentiation: a multicentre verification study

Kai-Lun Yu, Yi-Shiuan Tseng, Han-Ching Yang, Chia-Jung Liu, Po-Chih Kuo, Meng-Rui Lee, Chun-Da Huang, Lu-Cheng Kuo, Jann-Yuan Wang, Chao-Chi Ho, …
BMJ Open Respiratory Research, 卷.10(1), e001602
08/2023
PMID: 37532473

摘要

bronchoscopy lung cancer Pulmonary and Respiratory Medicine
Purpose Despite the importance of radial endobronchial ultrasound (rEBUS) in transbronchial biopsy, researchers have yet to apply artificial intelligence to the analysis of rEBUS images. Materials and methods This study developed a convolutional neural network (CNN) to differentiate between malignant and benign tumours in rEBUS images. This study retrospectively collected rEBUS images from medical centres in Taiwan, including 769 from National Taiwan University Hospital Hsin-Chu Branch, Hsinchu Hospital for model training (615 images) and internal validation (154 images) as well as 300 from National Taiwan University Hospital (NTUH-TPE) and 92 images were obtained from National Taiwan University Hospital Hsin-Chu Branch, Biomedical Park Hospital (NTUH-BIO) for external validation. Further assessments of the model were performed using image augmentation in the training phase and test-time augmentation (TTA). Results Using the internal validation dataset, the results were as follows: area under the curve (AUC) (0.88 (95% CI 0.83 to 0.92)), sensitivity (0.80 (95% CI 0.73 to 0.88)), specificity (0.75 (95% CI 0.66 to 0.83)). Using the NTUH-TPE external validation dataset, the results were as follows: AUC (0.76 (95% CI 0.71 to 0.80)), sensitivity (0.58 (95% CI 0.50 to 0.65)), specificity (0.92 (95% CI 0.88 to 0.97)). Using the NTUH-BIO external validation dataset, the results were as follows: AUC (0.72 (95% CI 0.64 to 0.82)), sensitivity (0.71 (95% CI 0.55 to 0.86)), specificity (0.76 (95% CI 0.64 to 0.87)). After fine-tuning, the AUC values for the external validation cohorts were as follows: NTUH-TPE (0.78) and NTUH-BIO (0.82). Our findings also demonstrated the feasibility of the model in differentiating between lung cancer subtypes, as indicated by the following AUC values: adenocarcinoma (0.70; 95% CI 0.64 to 0.76), squamous cell carcinoma (0.64; 95% CI 0.54 to 0.74) and small cell lung cancer (0.52; 95% CI 0.32 to 0.72). Conclusions Our results demonstrate the feasibility of the proposed CNN-based algorithm in differentiating between malignant and benign lesions in rEBUS images.

檔案與連結 (1)

url
https://doi.org/10.1136/bmjresp-2022-001602檢視
已出版(紀錄版本) 開放

相關連結

指標

1 檢視次數

詳細資料

Logo image