Development of a Novel Laboratory-Scale Testbed for Measuring the Iron Loss in a DAB Converter
期刊文章   同儕審查

Development of a Novel Laboratory-Scale Testbed for Measuring the Iron Loss in a DAB Converter

Yu-Chen Su 和 Keiji Wada
IEEE transactions on power electronics, 卷.41(7), 頁碼.10974-10986
01/07/2026
Web of Science ID: WOS:001741011300015

摘要

Accuracy Current measurement Dual-active-bridge (DAB) converter Iron iron loss measurement laboratory-scale testbed Loss measurement oscillation Oscilloscopes power regeneration resonance Switching frequency transformer with a nonunity turns ratio Transformers Voltage control voltage drop Voltage measurement Zero voltage switching
This article attempts to develop a new laboratory-scale testbed for measuring the iron loss within a dual-active-bridge (DAB) converter, particularly when using the transformer with a nonunity turns ratio. The regenerative construction is utilized to estimate the transformer under test, which is back-to-back connected to another transformer with the same turns ratio, enabling the usage of identical power converters on both sides. Accordingly, the proposed testbed uses two H-bridge converters fed by a common 50 V DC source and operated at a switching frequency of 20 kHz to feed two back-to-back connected transformers with a turns ratio of 1:7.8. With the help of power regeneration, the DC source needs only to cover the power loss rather than the power rating, thus reducing the burden of experimental equipment. However, the preliminary test results reveal two key issues that influence the measurement. To identify the root causes, theoretical discussions are conducted, and potential solutions are proposed in response to these two problems. The simulated waveforms are also provided and performed well in accordance with the experimental waveforms, and the iron loss measurement results are finally summarized to highlight that the developed system performs comparably to the actual DAB converter system. The proposed testbed is thus expected to be of practical value for transformer manufacturers to preliminarily measure the total iron loss of a DAB converter.

相關連結

指標

1 檢視次數

詳細資料

Logo image