Logo image
Development of an osteoblast-based 3D continuous-perfusion microfluidic system for drug screening
期刊文章   同儕審查

Development of an osteoblast-based 3D continuous-perfusion microfluidic system for drug screening

Kihoon Jang, Kae Sato, Kazuyo Igawa, Ung-Il ChungTakehiko Kitamori
Analytical and Bioanalytical Chemistry, 卷.390(3), 頁碼.825-832
02/2008
PMID: 18084748

摘要

Bioassays Cell systems Differentiation Microfluidics Osteoblast Shear stress Analytical Chemistry Biochemistry
In this work, we demonstrated that biological cells could be cultured in a continuous-perfusion glass microchip system for drug screening. We used mouse Col1a1GFP MC-3T3 E1 osteoblastic cells, which have a marker gene system expressing green fluorescent protein (GFP) under the control of osteoblast-specific promoters. With our microchip-based cell culture system, we realized automated long-term monitoring of cells and sampling of the culture supernatant system for osteoblast differentiation assay using a small number of cells. The system successfully monitored cells for 10 days. Under the 3D microchannel condition, shear stress (0.07 dyne/cm at a flow rate of 0.2 μL/min) was applied to the cells and it enhanced the GFP expression and differentiation of the osteoblasts. Analysis of alkaline phosphatase (ALP), which is an enzyme marker of osteoblasts, supported the results of GFP expression. In the case of differentiation medium containing bone morphogenetic protein 2, we found that ALP activity in the culture supernatant was enhanced 10 times in the microchannel compared with the static condition in 48-well dishes. A combined system of a microchip and a cell-based sensor might allow us to monitor osteogenic differentiation easily, precisely, and noninvasively. Our system can be applied in high-throughput drug screening assay for discovering osteogenic compounds. © 2007 Springer-Verlag.

相關連結

指標

1 檢視次數

詳細資料

Logo image