Logo image
Drug Response Assay System in a Microchip Using Human Hepatoma Cells
期刊文章   同儕審查

Drug Response Assay System in a Microchip Using Human Hepatoma Cells

Yuki Tanaka, Kiichi Sato, Masayuki Yamato, Teruo OkanoTakehiko Kitamori
Analytical Sciences, 卷.20(3), 頁碼.411-413
2004
PMID: 15068280

摘要

Analytical Chemistry
A microchip-based cell response assay system to an anticancer agent was developed. The hepatoma cell line HepG2 was used to assess the effects of an anticancer agent, doxorubicin. The required cell number was reduced by two orders, and the observation of the time course of cell response became possible. The system clearly showed that treatment with higher doses of the drug or longer exposure times gave more effects to cells. The possibilities of novel drug response studies or toxicity assay system were demonstrated.

相關連結

指標

1 檢視次數

詳細資料

Logo image