摘要
The method for the evaluation of the control room habitability is presented in this paper with focus on Maanshan PWR nuclear power plant (NPP) using the codes RADTRAD, HABIT, and ALOHA. Therefore, this paper is divided into two parts: The first part is the evaluation of the cumulative dose at the control room, the exclusion area boundary (EAB) and the low population zone (LPZ) in case of an design basis loss of coolant accident (DBA/LOCA). For this first part, the Maanshan NPP models of the code RADTRAD/SNAP were used for the analysis. The second part is the evaluation of the control room habit-ability under the assumption of CO 2 storage burst. For this part, the HABIT and ALOHA codes were used. As result it was seen that the RADTRAD calculation results are below the failure criteria of standard review plan (SRP) and 10 CFR 100.11. The HABIT and ALOHA results are below the R.G. 1.78 failure criteria. These results indicate that Maanshan NPP' habitability can be maintained under the above conditions.