Experimental study of air-water two-phase flow in an 8×8 rod bundle under pool condition for one-dimensional drift-flux analysis
期刊文章

Experimental study of air-water two-phase flow in an 8×8 rod bundle under pool condition for one-dimensional drift-flux analysis

Shao-Wen Chen, Yang Liu, Takashi Hibiki, Mamoru Ishii, Yoshitaka Yoshida, Ikuo Kinoshita, Michio MuraseKaichiro Mishima
International Journal of Heat and Fluid Flow, 卷.33(1), 頁碼.168-181
02/2012

摘要

Pool conditions Rod bundles Scale effect Two-phase flow Void fraction Condensed Matter Physics Mechanical Engineering Fluid Flow and Transfer Processes
In order to establish a reliable rod bundle database under pool conditions and to benchmark the existing models, a well-scaled 8 × 8 rod bundle test loop was designed based on the scaling criteria and a series of experiments was carried out with adiabatic air-water two-phase flow. Experiments for pool conditions covered the area-averaged void fraction 〈α〉 range of 0.12-0.93. Existing models and experimental data including boiling and air-water two-phase flow were compared and analyzed. Experimental results show that differences exist between large and small casing rod bundles as the flow structure changes with the casing scale. In addition, traditional drift-flux models for pipes may reflect the casing scale effect, but cannot be directly applied to the rod bundle geometry in pool conditions. Among the existing models for rod bundles, the Murase's model (1986), Kamei's model (2008) and Ishizuka's model (1995) give relatively better predictions in most regions. All benchmark results of existing models are tabulated in terms of void fraction prediction error for the present database. © 2011 Elsevier Inc.

相關連結

指標

1 檢視次數

詳細資料

Logo image