Logo image
Flow Resonance-Induced Temperature Rise for Thermal Impact Enhancement of Cavitation Reactor Systems
期刊文章   同儕審查

Flow Resonance-Induced Temperature Rise for Thermal Impact Enhancement of Cavitation Reactor Systems

Mou-Yung Liao, Sih-Li Chen, Li Xu, Yu-Hsiang Pan, Xin-Yuan Wu, Po-Hsien Wu, Jong-Fu Yeh, Yu-Yuan Hsieh, Kuan-Che Lan, Yi-Tung Chen, …
Applied sciences, 卷.16(12), 頁.5729
01/06/2026

摘要

Chemistry Chemistry, Multidisciplinary Engineering Engineering, Multidisciplinary Materials Science Materials Science, Multidisciplinary Physical Sciences Physics Physics, Applied Science & Technology Technology
It has been observed in prior research that high thermal impact-resulting from a large temperature difference between hot water vapor and cold liquid water-can enhance the thermal performance of cavitation-induced low-energy nuclear reactions (LENRs) in water, with an estimated increase in the coefficient of performance (COP) of approximately 50% for every 100 degrees C temperature rise. The temperature of the hot water vapor is primarily determined by the boiler output, which typically represents the highest temperature source and plays a dominant role in reactor performance. In this study, a flow oscillator was designed as an thermal conditioning component for these potential LENR reactor systems using linear flow network analysis (LFNA) to generate flow resonance that elevates the hot vapor temperature, thereby increasing thermal impact and improving LENR performance. LFNA is based on the linearization of the fluid flow equations governing mass and momentum transport and utilizes a fluid-electric circuit analogy. For a fluid flow system, various components can be modeled using analogs of electrical resistance, capacitance, and inductance (R, C, and L), allowing the system behavior to be analyzed similarly to an RLC circuit. Through this analogy, flow resonance phenomena can be predicted, potentially enabling the generation of high-temperature and high-pressure responses that are beneficial to LENR processes. The analytical model was experimentally validated and subsequently applied in the LENR reactor design. The analytical result shows that an output temperature difference exceeding 350 degrees C can be achieved using a 0.5 m pulse tube at a 46 Hz triggering frequency with 20 kPa perturbation, which indicates a potential COP enhancement of 175% based on prior studies. The result provides a potential mechanism to significantly enhance the thermal impact conditions and promote LENR performance in water-based reactor systems.

檔案與連結 (1)

url
https://doi.org/10.3390/app16125729檢視
已出版(紀錄版本) 開放

相關連結

指標

1 檢視次數

詳細資料

Logo image