Logo image
High reproducibility of tumor hypoxia evaluated by F- fluoromisonidazole pet for head and neck cancer
期刊文章   同儕審查

High reproducibility of tumor hypoxia evaluated by F- fluoromisonidazole pet for head and neck cancer

Shozo Okamoto, Tohru Shiga, Koichi Yasuda, Yoichi M. Ito, Keiichi Magota, Katsuhiko Kasai, Yuji Kuge, Hiroki Shirato, Nagara Tamaki 和 Fang-Hsin Chen
The Journal of nuclear medicine (1978), 卷.54(2), 頁碼.201-207
02/2013
Web of Science ID: WOS:000314691200019

摘要

F-FMISO Head and neck cancer Reproducibility Tumor hypoxia

Tumor hypoxia is well known to be radiation resistant. F-18-fluoromisonidazole (F-18-FMISO) PET has been used for noninvasive evaluation of hypoxia. Quantitative evaluation of F-18-FMISO uptake is thus expected to play an important role in the planning of dose escalation radiotherapy. However, the reproducibility of F-18-FMISO uptake has remained unclarified. We therefore investigated the reproducibility of tumor hypoxia by using quantitative analysis of F-18-FMISO uptake. Methods: Eleven patients with untreated head and neck cancer underwent 2 F-18-FMISO PET/CT scans (F-18-FMISO1 and F-18-FMISO2) with a 48-h interval prospectively. All images were acquired at 4 h after F-18-FMISO injection for 10 min. The maximum standardized uptake (SUVmax), tumor-to-blood ratio (TBR), and tumor-to-muscle ratio (TMR) of F-18-FMISO uptake were statistically compared between the 2 F-18-FMISO scans by use of intraclass correlation coefficients (ICCs). The hypoxic volume was calculated as the area with a TBR of greater than or equal to 1.5 or the area with a TMR of greater than or equal to 1.25 to assess differences in hypoxic volume between the 2 F-18-FMISO scans. The distances from the maximum uptake locations of the F-18-FMISO1 images to those of the F-18-FMISO2 images were measured to evaluate the locations of F-18-FMISO uptake. Results: The SUVmax (mean +/- SD) for F-18-FMISO1 and F-18-FMISO2 was 3.16 +/- 1.29 and 3.02 +/- 1.12, respectively, with the difference between the 2 scans being 7.0% +/- 4.6%. The TBRs for F-18-FMISO1 and F-18-FMISO2 were 2.98 +/- 0.83 and 2.97 +/- 0.64, respectively, with a difference of 9.9% +/- 3.3%. The TMRs for F-18-FMISO1 and F-18-FMISO2 were 2.25 +/- 0.71 and 2.19 +/- 0.67, respectively, with a difference of 7.1% +/- 5.3%. The ICCs for SUVmax, TBR, and TMR were 0.959, 0.913, and 0.965, respectively. The difference in hypoxic volume based on TBR was 1.8 +/- 1.8 mL, and the difference in hypoxic volume based on TMR was 0.9 +/- 1.3 mL, with ICCs of 0.986 and 0.996, respectively. The maximum uptake locations of the F-18-FMISO1 images were different from those of the F-18-FMISO2 images and were within the full width at half maximum of the PET/CT scanner, except in 1 case. Conclusion: The values for F-18-FMISO PET uptake and hypoxic volume in head and neck tumors between the 2 F-18-FMISO scans were highly reproducible. Such high reproducibility of tumor hypoxia is promising for accurate radiation planning.

檔案與連結 (1)

url
https://doi.org/10.2967/jnumed.112.109330檢視
已出版(紀錄版本) 開放

相關連結

指標

1 檢視次數

詳細資料

Logo image