Logo image
Improved performance of highly sensitive room-temperature ammonia gas sensor with P-type doping carbazole-triazine derivative
期刊文章   同儕審查

Improved performance of highly sensitive room-temperature ammonia gas sensor with P-type doping carbazole-triazine derivative

Yu-Hsiang Cheng, Chien-Chih Chen, Li-Yin Chen, Yi-Jyun Ma, Hsuang-Kai Hsiao, Ying-Chang Lu, Jung-Kang Tu, Hsiao-Wen Zan, Hsin-Fei Meng, Hao-Wu Lin, …
Journal of the Taiwan Institute of Chemical Engineers, 卷.174, 106197
09/2025
Web of Science ID: WOS:001499786800001

摘要

Ammonia gas sensor DIC-TRZ Highly sensitive p-type doping Room-temperature gas Sensor
•A Room temperature ammonia gas sensor using DIC-TRZ is demonstrated.•The ammonia detection range presented in this work is 100 to 2000 ppb.•The operation current of the DIC-TRZ sensor is stable.•With F4-TCNQ dopant, the operation current of the sensor is increased to 25-fold.•The real-time current reading of the sensor can be implemented by a low-cost multimeter. The detection and monitoring of ammonia (NH₃) gas are critical for various applications, including environmental monitoring, industrial safety, and medical diagnostics. NH₃ is a significant biomarker for chronic kidney disease and the effectiveness of hemodialysis, requiring sensors capable of detecting ppb-level concentrations. While advanced analytical techniques meet the sensitivity requirements, their high cost and complex instrumentation limit practical applications. Developing cost-effective, highly sensitive, and user-friendly ammonia sensors remains a priority. This study presents a room-temperature NH₃ gas sensor based on 2,4-diphenyl-6-bis(12-phenylindolo)[2,3-a]carbazole-11-yl)-1,3,5-triazine (DIC-TRZ), a material known for its high carrier mobility and stable electrical properties. The sensor was integrated into a vertical nano-junction device structure, and its performance was enhanced using a p-type doping strategy with 1 wt % F4-TCNQ. The operational current, sensitivity, limit of detection (LOD), stability, and selectivity were systematically evaluated. The DIC-TRZ-based sensor demonstrated excellent ammonia detection performance, with a sensitivity of 0.0467 %/ppb and an LOD of 20.7 ppb for the non-doped device, and a sensitivity of 0.0391 %/ppb and an LOD of 16.0 ppb for the doped device. The sensor exhibited rapid response and recovery times and a stable operational current. The doping strategy increased the current by nearly two orders of magnitude, reaching ∼10⁻⁵ A, significantly improving the signal-to-noise ratio. This enhancement enabled real-time current measurement using a low-cost multimeter, broadening the applicability for environmental monitoring, medical diagnostics, and portable applications. [Display omitted]

相關連結

詳細資料

Logo image