Logo image
Investigation on two-phase distribution in a vibrating annulus
期刊文章   同儕審查

Investigation on two-phase distribution in a vibrating annulus

Xiu Xiao, Qingzi Zhu, Shao-Wen Chen, Yajun Zhang, Haijun Jia 和 Mamoru Ishii
Annals of Nuclear Energy, 卷.108, 頁碼.67-78
10/2017

摘要

Flow distribution Influence parameters Two-phase flow Vibrating annulus Vibration amplitude Nuclear Energy and Engineering
Seismic vibration can induce additional interphase forces acting on bubbles and change flow characteristics in two-phase flow system. Local measurements of air-water two-phase flow parameters, namely void fraction, interfacial area concentration and Sauter mean diameter, were conducted in a vibrating annulus. The vibration acceleration ranged from 0.05 g to 0.24 g. Nine inlet flow conditions were selected, which covered bubbly and slug flows. No significant difference was observed in the time-averaged flow parameters between reference and vibration experiments. During vibration cycle, the radial two-phase flow distribution varied continuously with vibration phase. The change in non-dimensional line-averaged void fraction decreased with the increase of void fraction. As the vibration amplitude increased from 3.04 mm to 10.08 mm, the vibration effects on variations of local flow parameters were greatly enhanced with the mean relative variation (MRV) of void faction reached up to 55%. The study on MRV of local parameters showed that the vibration effects were strongly related to specific flow conditions. With the increase of superficial gas velocity and void fraction, the vibration effects were reduced and the MRV of void fraction decreased from 55% to 18%.