Logo image
Mapping Receptor Density on Live Cells by Using Fluorescence Correlation Spectroscopy
Journal article   Peer reviewed

Mapping Receptor Density on Live Cells by Using Fluorescence Correlation Spectroscopy

Yan Chen, Alina C. Munteanu, Yu-Fen Huang, Joseph Phillips, Zhi Zhu, Michael Mavros and Weihong Tan
Chemistry - A European Journal, Vol.15(21), pp.5327-5336
18/05/2009

Abstract

Aptamers Fluorescence spectroscopy Ligand-receptor interactions Receptors
Study of the density, spatial distribution, and molecular interactions of receptors on the cell membrane provides the knowledge required to understand cellular behavior and biological functions, as well as to discover, design, and screen novel therapeutic agents. However, the mapping of receptor distribution and the monitoring of ligand- receptor interactions on live cells in a spatially and temporally ordered manner are challenging tasks. In this paper, we apply fluorescence correlation spectroscopy (FCS) to map receptor densities on live cell membranes by introducing fluorescently marked apta- mer molecules, which specifically bind to certain cell-surface receptors. The femtoliter-sized (0.4 fL) observation volume created by FCS allows fluores- cent-aptamer detection down to 2 molecules and appears to be an ideal and highly sensitive biophysical tool for studying molecular interactions on live cells. Fluorophore-labeled aptamers were chosen for receptor recognition because of their high binding affinity and specificity. Aptamer sgc8, generated for specific cell recognition by a process called cell systematic evolution of ligands by exponential enrichment, was determined by FCS to have a binding affinity in the picomolar range (dissociation constant K d = 790 ± 150 pM) with its target membrane receptor, human protein tyrosine kinase-7 (PTK7), a potential cancer biomarker. We then constructed a cellular model and applied this aptamer-receptor interaction to estimate receptor densities and distributions on the cell surface. Specifically, different expression levels of PTK7 were studied by using human leukemia CCRF-CEM cells (1300 ± 190 receptors μm -2 ) and HeLa cervical cancer cells (550 ± 90 receptors μm -2 ). Competition studies with excess nonla- beled aptamers and proteinase treatment studies proved the validity of the density-estimation approach. With its intrinsic advantages of direct measurement, high sensitivity, fast analysis, and single-cell measurement, this FCS density-estimation approach holds potential for future applications in molecular-interaction studies and density estimations for subcellular structures and membrane receptors..

Metrics

1 Record Views
116 readers on Mendeley

Details

Logo image