Logo image
Minimizing switching noise in a power distribution network using external coupled resistive termination
Journal article   Open access   Peer reviewed

Minimizing switching noise in a power distribution network using external coupled resistive termination

IEEE Transactions on Advanced Packaging, Vol.28(4), pp.754-760
11/2005

Abstract

High-speed digital system Power distribution network Printed circuit board (PCB) Quality factor Resonance Simultaneous switching noise
Switching noise-induced voltage fluctuation might result in a serious timing skew or false triggering in a high-speed digital system. We propose a new approach called external coupled resistive termination (ECRT) for suppressing this noise. Analyzing the resonant field patterns reveals that the bulk noise is accumulated close to the plane edges because of the open-end boundary condition. Thus, adding extra loading at the field bulk effectively reduces the quality factors and consequently minimizes the noise accumulation. A Y-shaped power distribution network was studied with a frequency controllable input-output (I/O) buffer model. Simulation results indicate that the noise level is significantly suppressed. The optimal noise reduction rate is 80% at resonance with an overall reduction rate of 50%. Scattered placement of the ECRT was also investigated and the corresponding noise reduction rate was 50%. Reasons for that will be discussed. © 2005 IEEE.
pdf
Minimizing_switching_noise_in_a_power_distribution_network_using_external_coupled_resistive_termination.pdfDownloadView
Open Access

Related links

Metrics

1 Record Views

Details

Logo image