NTCP modeling analysis of acute hematologic toxicity in whole pelvic radiation therapy for gynecologic malignancies – A dosimetric comparison of IMRT and spot-scanning proton therapy (SSPT)
期刊文章   同儕審查

NTCP modeling analysis of acute hematologic toxicity in whole pelvic radiation therapy for gynecologic malignancies – A dosimetric comparison of IMRT and spot-scanning proton therapy (SSPT)

Takaaki Yoshimura, Rumiko Kinoshita, Shunsuke Onodera, Chie Toramatsu, Ryusuke Suzuki, Yoichi M. Ito, Seishin Takao, Taeko Matsuura, Yuka Matsuzaki, Kikuo Umegaki, …
Physica medica, 卷.32(9), 頁碼.1095-1102
01/09/2016
PMID: 27567089
Web of Science ID: WOS:000390594600007

摘要

LKB-NTCP model analysis Spot-scanning proton therapy Treatment planning study Whole pelvic radiation therapy
•This dosimetric study includes 13 postoperative gynecological malignancy patients.•Spot-scanning proton therapy (SSPT) was compared to IMRT in whole pelvic radiotherapy.•The dose to the bone marrow and the risk of hematologic toxicity (HT) were compared.•Bone marrow dose using SSPT were significantly lower than IMRT (p=0.0002).•NTCP value for the risk of HT using SSPT was significantly lower than IMRT (p=0.0002). This treatment planning study was conducted to determine whether spot scanning proton beam therapy (SSPT) reduces the risk of grade ⩾3 hematologic toxicity (HT3+) compared with intensity modulated radiation therapy (IMRT) for postoperative whole pelvic radiation therapy (WPRT). The normal tissue complication probability (NTCP) of the risk of HT3+ was used as an in silico surrogate marker in this analysis. IMRT and SSPT plans were created for 13 gynecologic malignancy patients who had received hysterectomies. The IMRT plans were generated using the 7-fields step and shoot technique. The SSPT plans were generated using anterior-posterior field with single field optimization. Using the relative biological effectives (RBE) value of 1.0 for IMRT and 1.1 for SSPT, the prescribed dose was 45Gy(RBE) in 1.8Gy(RBE) per fractions for 95% of the planning target volume (PTV). The homogeneity index (HI) and the conformity index (CI) of the PTV were also compared. The bone marrow (BM) and femoral head doses using SSPT were significantly lower than with IMRT. The NTCP modeling analysis showed that the risk of HT3+ using SSPT was significantly lower than with IMRT (NTCP=0.04±0.01 and 0.19±0.03, p=0.0002, respectively). There were no significant differences in the CI and HI of the PTV between IMRT and SSPT (CI=0.97±0.01 and 0.96±0.02, p=0.3177, and HI=1.24±0.11 and 1.27±0.05, p=0.8473, respectively). The SSPT achieves significant reductions in the dose to BM without compromising target coverage, compared with IMRT. The NTCP value for HT3+ in SSPT was significantly lower than in IMRT.

檔案與連結 (1)

url
https://doi.org/10.1016/j.ejmp.2016.08.007檢視
已出版(紀錄版本) 開放

相關連結

詳細資料

Logo image