Phase-contrast magnetic resonance imaging for the evaluation of wall shear stress in the common carotid artery of a spontaneously hypertensive rat model at 7 T: Location-specific change, regional distribution along the vascular circumference, and reproducibility analysis
期刊文章

Phase-contrast magnetic resonance imaging for the evaluation of wall shear stress in the common carotid artery of a spontaneously hypertensive rat model at 7 T: Location-specific change, regional distribution along the vascular circumference, and reproducibility analysis

Shin-Lei Peng, Fu-Nien Wang, Tao-Chieh Yang, Jee-Ching Hsu, Yi-Chun WuHsu-Hsia Peng
Magnetic Resonance Imaging, 卷.34(5), 頁碼.624-631
06/2016
PMID: 26712655

摘要

Flow measurement Phase-contrast magnetic resonance imaging Spontaneously hypertensive rat Wall shear stress Biophysics Biomedical Engineering Radiology Nuclear Medicine and Imaging
Purpose: To measure wall shear stress (WSS) in the common carotid arteries (CCA) of a spontaneously hypertensive rat (SHR) model and a normotensive Wistar Kyoto rat (WKY) model by 2D phase-contrast magnetic resonance imaging (PC-MRI). Materials and methods: PC-MRI was performed on 7 SHR and 7 WKY at ages of 4 and 7 months at a 7 T scanner. Images in the middle CCA (CCA <sub>mid</sub> ) and in the bifurcation of CCA (CCA <sub>bifur</sub> ) were acquired. The WSS values for differentiating characteristics between two models were calculated. Further, its location-specific change, regional distribution along the CCA circumference, and the reproducibility were evaluated. Results: In the 4-month-old rats, SHR showed lower temporal averaged WSS (WSS <sub>avg</sub> ) and peak systolic WSS (WSS <sub>s</sub> ) in the CCA <sub>bifur</sub> in comparison with WKY (WSS <sub>avg</sub> : 0.95 ± 0.18 vs. 1.30 ± 0.36 N/m <sup>2</sup> (P < 0.01); WSS <sub>s</sub> : 1.68 ± 0.70 vs. 3.22 ± 2.49 N/m <sup>2</sup> (P < 0.05)). We observed the same trends in the 7-month-old rats. In the SHR model, the WSS <sub>avg</sub> was lower in the CCA <sub>bifur</sub> than in the CCA <sub>mid</sub> . The regional distribution of WSS <sub>avg</sub> along the circumference of CCA showed lower values in WKY, particularly in posterior segments of CCA <sub>bifur</sub> . The intra-observer, intra-scan and inter-scan reproducibility was acceptable and the disagreements were ranged from -0.05 to 0.06 N/m <sup>2</sup> . Conclusion: This study evaluated WSS in SHR and WKY models by 2D PC-MRI. High reproducibility analyses further indicated the reliability of measurements of WSS in the CCA of SHR and WKY models using PC-MRI at 7 T.

相關連結

指標

1 檢視次數

詳細資料

Logo image