摘要
•Transonic backward-facing step flow with vortex generators has been analyzed by pressure-sensitive paint and oil flow visualization.•Oil flow visualization results were found to be similar to those of the pressure-sensitive-paint measurements.•Pressure-sensitive paint approach provided more detailed information by depicting two-dimensional pressure distributions.
This study investigates the distribution of pressure around a 5-mm-high backward-facing step model and counter-rotating vane vortex generators in a transonic wind tunnel by applying pressure-sensitive paint. Vortex generators with heights of 0.0, 0.2, 0.5, and 1.0 relative to the thickness of the turbulent boundary layer were used under transonic flow conditions at Mach numbers of 0.8 and 0.9. Oil flow visualization results were found to be similar to those of the pressure-sensitive paint measurements in terms of reattachment length and flow characteristics. This direct comparison not only confirms the reliability of PSP but also demonstrates its superior ability to visualize complex pressure distributions. Although the oil flow visualization technique effectively depicted the flow patterns, the pressure-sensitive paint approach provided more detailed information by depicting two-dimensional pressure distributions and identifying low-pressure regions around the vortex generators. Among all configurations, the vortex generator with h* = 0.5 was found to be the most effective in shortening the recirculation region and advancing the reattachment point under both Mach numbers.