Respiration-averaged CT for attenuation correction of PET Images - Impact on PET Texture Features in Non-Small Cell Lung Cancer Patients
期刊文章   開放取用(OA)

Respiration-averaged CT for attenuation correction of PET Images - Impact on PET Texture Features in Non-Small Cell Lung Cancer Patients

Nai-Ming Cheng, Yu-Hua Dean Fang, Din-Li Tsan, Ching-Han HsuTzu-Chen Yen
PLoS ONE, 卷.11(3), e0150509
03/2016
PMID: 26930211

摘要

Biochemistry Genetics and Molecular Biology (all) Agricultural and Biological Sciences (all)
Purpose We compared attenuation correction of PET images with helical CT (PET/HCT) and respiration- averaged CT (PET/ACT) in patients with non-small-cell lung cancer (NSCLC) with the goal of investigating the impact of respiration-averaged CT on 18F FDG PET texture parameters. Materials and Methods A total of 56 patients were enrolled. Tumors were segmented on pretreatment PET images using the adaptive threshold. Twelve different texture parameters were computed: standard uptake value (SUV) entropy, uniformity, entropy, dissimilarity, homogeneity, coarseness, busyness, contrast, complexity, grey-level nonuniformity, zone-size nonuniformity, and high grey-level large zone emphasis. Comparisons of PET/HCT and PET/ACT were performed using Wilcoxon signed-rank tests, intraclass correlation coefficients, and Bland-Altman analysis. Receiver operating characteristic (ROC) curves as well as univariate and multivariate Cox regression analyses were used to identify the parameters significantly associated with disease-specific survival (DSS). A fixed threshold at 45% of the maximum SUV (T45) was used for validation. Results SUV maximum and total lesion glycolysis (TLG) were significantly higher in PET/ACT. However, texture parameters obtained with PET/ACT and PET/HCT showed a high degree of agreement. The lowest levels of variation between the two modalities were observed for SUV entropy (9.7%) and entropy (9.8%). SUV entropy, entropy, and coarseness from both PET/ACT and PET/HCT were significantly associated with DSS. Validation analyses using T45 confirmed the usefulness of SUV entropy and entropy in both PET/HCT and PET/ACT for the prediction of DSS, but only coarseness from PET/ACT achieved the statistical significance threshold. Conclusions Our results indicate that 1) texture parameters from PET/ACT are clinically useful in the prediction of survival in NSCLC patients and 2) SUV entropy and entropy are robust to attenuation correction methods.

檔案與連結 (1)

url
https://doi.org/10.1371/journal.pone.0150509檢視
已出版(紀錄版本) 開放

相關連結

指標

1 檢視次數

詳細資料

Logo image