Abstract
Chinshan nuclear power plant (NPP), a BWR/4 plant, is the first NPP in Taiwan. After Fukushima NPP disaster occurred, there is more concern for the safety of NPPs in Taiwan. Therefore, in order to estimate the safety of Chinshan NPP spent fuel pool (SFP), by using TRACE, MELCOR, CFD, and FRAPTRAN codes, INER (Institute of Nuclear Energy Research, Atomic Energy Council, R.O.C.) performed the safety analysis of Chinshan NPP SFP. There were two main steps in this research. The first step was the establishment of Chinshan NPP SFP models. And the transient analysis under the SFP cooling system failure condition (Fukushima-like accident) was performed. In addition, the sensitive study of the time point for water spray was also performed. The next step was the fuel rod performance analysis by using FRAPTRAN and TRACE's results. Finally, the animation model of Chinshan NPP SFP was presented by using the animation function of SNAP with MELCOR analysis results.