Logo image
Study of piezoelectrically actuated micropumps with multiple parallel chambers
Journal article   Peer reviewed

Study of piezoelectrically actuated micropumps with multiple parallel chambers

Y.H. Guu, H. Hocheng and C.H. Chang
Materials and Manufacturing Processes, Vol.23(2), pp.210-215
02/2008

Abstract

Diffuser Flow rate Gaussian Laser doppler vibrometer (LDV) Lorentzian Membrane Microfluidic system Microvalve Multiparallel chambers Nonlinear regression Nozzle Paraboloid Parallel micropumps Piezoelectric actuator Single micropump
This study investigated the performance of the piezoelectrically actuated parallel micropumps. The displacement of the piezoelectric (PZT) actuator and the flow rate of the micropump were studied in terms of operating parameters. Using a nonlinear regression technique, empirical models of the micropumps were established based on the experimental data. The experimental results indicated that the displacement of the piezoelectric actuator increased with actuating voltage but decreased with frequency. The flow rate of the micropump was proportional to the applied voltage and demonstrated that the maximum flow rate occurred at an adequate frequency. When operated at a voltage of 140V and a frequency of 20Hz, the single micropump delivered a maximum flow rate of 91 1/min. At the same input signal, the maximum flow rate of the double parallel micropump was 1.5 times that of the single micropump, and approximately twice that of the single micropump for triple parallel operation. Furthermore, the obtained non-linear regression formulae can be utilized to predict the flow rate of the micropump with multiparallel chambers.

Metrics

1 Record Views

Details

Logo image