Logo image
Sustainable relay strategy for the synthesis of d-glucose-based poly ionic liquid and its fabrication on carbon electrode for simultaneous detection of chromium (VI) and lead (II) in environmental waters
期刊文章   同儕審查

Sustainable relay strategy for the synthesis of d-glucose-based poly ionic liquid and its fabrication on carbon electrode for simultaneous detection of chromium (VI) and lead (II) in environmental waters

Krishnaraj P, Lokesh Kumar Sugumar, Bhulakshmi Sathi, Chun-Cheng Lin, Sheng-Kai Wang, Kishore K.R. Tetala 和 Sabbasani Rajasekhara Reddy
Chemical engineering journal (Lausanne, Switzerland : 1996), 卷.522, 頁.167488
15/10/2025
Web of Science ID: WOS:001562703000001

摘要

Chromium d-Glucose-based poly ionic liquids Electrochemical sensor ICP-OES Lead
Water pollutants such as chromium (Cr (VI)) and lead (Pb (II)) ions pose significant threat to human health. The major challenges lies in the development of a sensitive and selective system to detect those toxic metal-ions in the drinking water within the recommended limits set by US EPA and WHO. This study presents the design and synthesis of hydrophobic d-Glucose-based poly ionic liquids (GPILs) via a cost-effective sustainable relay strategy. The synthesized GPIL was characterized using FT-IR, NMR and TGA, respectively. For the first time, a GPIL based electrode (on glassy carbon electrode (GCE)) was fabricated via sequential drop-cast approach involving the use of both multi-walled carbon nanotubes (MWCNTs) and GPILs. The physical and electrochemical characterization studies have confirmed the interaction of GPIL with MWCNTs on the electrode surface. GPIL@MWCNT/GCE exhibited separate reduction signals for both Cr (VI) (+0.45 V vs Ag/AgCl) and Pb (II) (−0.63 V vs Ag/AgCl), and an excellent limit of detection (LOD) (9.8 ppb for Cr (VI) and 12.5 ppb for Pb (II)), respectively. The GPIL@MWCNT/GCE was successfully translated to a use and throw-electrode strip (screen printed carbon electrode; GPIL@MWCNT/SPCE). GPIL@MWCNT/SPCE has, for the first time, simultaneously detected both Cr (VI) and Pb (II) in 6 water samples collected from an industrial area in India. The obtained values are similar to the values detected using inductively coupled plasma optical emission spectrometry (ICP-OES). •Relay synthesis of hydrophobic d-Glucose-based poly ionic liquids (GPILs)•Successful fabrication of GPILs in a use and throw electrochemical strip•Excellent limit of detection for Chromium (9.8 ppb) and Lead (12.5 ppb)•Simultaneous detection of both Chromium and Lead in 6 water samples•Metal ion detection performance of electrochemical strip was similar to ICP-OES.

檔案與連結 (1)

url
https://www.sciencedirect.com/science/article/pii/S1385894725083275檢視
已出版(紀錄版本)

相關連結

InCites亮點

本研究成果之相關指標(擷取自 InCites Benchmarking & Analytics)

合作類型
機構合作
國際合作
引用書目主題
2 Chemistry
2.145 Biosensors
2.145.561 Anodic Stripping Voltammetry
Web Of Science研究領域
Engineering, Chemical
Engineering, Environmental
ESI研究領域
Engineering

詳細資料

Logo image