Abstract
A high-reflection band in the short-wavelength region for Herpinequivalent gradient index layer system was found and analysed numerically. The band shape and edge position are sensitive to the number of steps for which the gradient index layer is divided and the Herpin transfer wavelength. The existence of the band is independent of the index profile. The existence of the band was also experimentally verified. © 1991 Taylor & Francis Ltd.