The utilization of optically-induced-dielectrophoresis (ODEP)-based virtual cell filters in a microfluidic system for continuous isolation and purification of circulating tumour cells (CTCs) based on their size characteristics
期刊文章   同儕審查

The utilization of optically-induced-dielectrophoresis (ODEP)-based virtual cell filters in a microfluidic system for continuous isolation and purification of circulating tumour cells (CTCs) based on their size characteristics

Wen-Pin Chou, Hung-Ming Wang, Jyun-Huan Chang, Tzu-Keng Chiu, Chia-Hsun Hsieh, Chia-Jung Liao, Min-Hsien Wu 和 Jason Chia-Hsun Hsieh
Sensors and actuators. B, Chemical, 卷.241, 頁碼.245-254
31/03/2017
Web of Science ID: WOS:000393253700031

摘要

Cancer cells Cell isolation Circulating tumor cells (CTCs) Microfluidics Optically induced dielectrophoresis (ODEP)
•Optically induced dielectrophoresis (ODEP), and flow velocity control are integrated in a microfluidic system for cell isolation.•A four-cascade cell isolation is implemented for a higher-resolution cell separation, and thus higher-purity cell isolation.•The method is able to isolate cancer cells in a high cell purity manner (94.9±0.3%). High purity isolation of circulating tumor cells (CTCs) is important for their subsequent gene-related analysis. Nevertheless, the conventional CTC isolation schemes might not be able to avoid the contamination of leukocytes in a treated sample. To address this issue, we proposed to integrate the technique of optically induced dielectrophoresis (ODEP)-based cell manipulation, and flow velocity control in a microfluidic system for further isolating CTCs after a conventional CTC isolation process. The working principle was based on the cell size difference between the CTCs and leukocytes. In the ODEP microfluidic system, a four-cascade cell isolation using four optical light-based virtual cell filters was designed. Based on this, four different selection conditions were simultaneously implemented for a higher-resolution cell separation, and thus higher-purity cell isolation. In this work, the ODEP microfluidic system was designed and fabricated. Moreover, the optimal ODEP operating conditions such as light bar width (40μm), gap (80μm), and number (4), as well as the sample flow rate (0.4μlmin−1) were experimentally determined. Results revealed the presented method was able to isolate cancer cells with cell purity as high as 94.9±0.3% (cancer cell recovery rate: 54±7%). Overall, this study has presented an ODEP microfluidic system capable of refining CTC purity after a conventional CTC isolation process.

相關連結

詳細資料

Logo image