Logo image
Utility of noncontrast-enhanced time-resolved four-dimensional MR angiography with a vessel-selective technique for intracranial arteriovenous malformations
期刊文章   同儕審查

Utility of noncontrast-enhanced time-resolved four-dimensional MR angiography with a vessel-selective technique for intracranial arteriovenous malformations

Noriyuki Fujima, Toshiya Osanai, Yukie Shimizu, Atsushi Yoshida, Taisuke Harada, Naoki Nakayama, Kohsuke Kudo, Kiyohiro Houkin, Hiroki Shirato 和 Fang-Hsin Chen
Journal of magnetic resonance imaging, 卷.44(4), 頁碼.834-845
10/2016
PMID: 26970348
Web of Science ID: WOS:000384646700007

摘要

Adolescent Adult Aged Cerebral Angiography - methods Child Child, Preschool Contrast Media Female Humans Image Enhancement - methods Image Interpretation, Computer-Assisted - methods Imaging, Three-Dimensional - methods Intracranial Arteriovenous Malformations - diagnostic imaging Intracranial Arteriovenous Malformations - pathology Magnetic Resonance Angiography - methods Male Middle Aged Reproducibility of Results Sensitivity and Specificity Signal Processing, Computer-Assisted Young Adult
To evaluate the utility of a vessel-selective four-dimensional (4D) magnetic resonance angiography (MRA) technique for the evaluation of intracranial arteriovenous malformations (AVMs). Twelve AVM patients were evaluated retrospectively. Time-of-flight (TOF) MRA, nonvessel-selective 4D-MRA (NS-4D-MRA), and vessel-selective 4D-MRA (VS-4D-MRA) were performed using a 3T MR unit in all patients, and used to identify feeding arteries and draining veins and measure nidus size. The diagnostic accuracy of the three techniques was compared using digital subtraction angiography (DSA). If a multifeeder was observed, the percentage of blood flow of each feeding artery to the entire nidus was evaluated and compared to the DSA findings using the "error value," defined as the degree of overestimation of the blood flow. All imaging findings were assessed by two neuroradiologists. In both raters, the detectability of feeding arteries by VS-4D-MRA (12 and 11 patients) was significantly higher than those of TOF-MRA (7 and 6 patients) and NS-4D-MRA (8 and 7 patients) (P < 0.016). The detectability of drainer veins by TOF-MRA (10 and 10 patients) was significantly higher than that of VS-4D-MRA (7 and 6 patients). In the percentage of the blood flow of each feed artery to the entire nidus, the DSA findings (error value; 27.1 ± 5.7) indicated overestimations of the blood flow compared to the VS-4D-MRA (error value; 7.1 ± 3.9) (P < 0.001). VS-4D-MRA was shown to be a useful technique for the evaluation of intracranial AVMs, especially for detecting feed arteries and estimating details of the nidus structure. J. MAGN. RESON. IMAGING 2016;44:834-845.

相關連結

詳細資料

Logo image